Armstrong air ultra v tech 91 parts

Armstrong air ultra v tech 91 parts. The fanG2D95 Ultra V Tech 91 Enhanced 95 LUF80. If that’s the only component in the system, then two wires is all you need. Compare it with other models like the 79A5201 and find the best deal on Amazon. Their top to loyal site are 10 15 years of Armstrong Air Ultra V Tech 91 I have an Armstrong Air Ultra 5, tech 80 Furnace. S1-02426087000 York 1/2 H. 5 All models beginning with G1D93 Air-Ease Ultra V Advantage 93 II Gas 92. When an Armstrong Air professional comes to your home for service or maintenance, he or she should offer the following services to help keep your system at its best. There is flame rollout occuring. In warmer climates, the thoughtful and efficient design of Armstrong Air air handlers mean efficiency and reliability season after season. Label the wires before removing any of them. The furnace has two panels that can be taken off by lifting straight up to expose Furnace Draft Air Pressure Switch, 2 Stage (. The Armstrong ultra sx 80 furnace parts diagram Armstrong Air Ultra V Tech 91 Furnace Manual, Telsta T40c Parts Manual, Manual Fax Brother 775 Espaol, Soltek Sl-kt400a-c User Manual, Kia Manual Repair, Marshall Avt412 Manual, Denon Avr 900 Manual Pdf Sep 5, 2016 · I have a CT3200 thermostat and my furnace is an Armstrong Air Ultra V Tech 80, model number 45647-001 or 45735-001 (both numbers are on the panels). 48. $152. Feb 21, 2022 · Armstrong Air Ultra V Tech 91 Manual >>> DOWNLOAD This is the ignition sequence on my 8 year old Armstrong Air furnace. Malfunctions covered after the manufacturer's warranty. Armstrong 10Y54 programmed control module. Explore the Armstrong Air Pro Jan 31, 2010 · Hi, I was having a problem with my Armstrong air ultra v tech 80. Pull the stat cover off to expose control wiring. 92. View Profile View Forum Posts Private 4 Armstrong Air Ultra 5 Tech 91 Manual 2023-08-06 Cornell University Press Ultrawideband (UWB) communication systems offer an unprecedented opportunityto impact the future communication world. If it has an W1 and W2 terminal with wires on them then you need a 2 stage tstat. The fan G2D95 Ultra V Tech 91 Enhanced 95 LUF80. Add selected to cart. - Answered by a verified HVAC TechnicianI have an Armstrong Air Ultra 5, tech 80 Furnace. 3" Diameter 115/230V Refrigeration Motor Canada. My wife and I think this furnace was in our house before the previous occupants added a large addition and that it under-powered to handle the size of the home. 38. 3 Armstrong Air Heating Products - Air-Ease Ultra V Advantage 93 92. Dec 31, 2015 · Armstrong Air Ultra V Tech 80. Armstrong Air Ultra V Tech 91 FurnacesArmstrong Air Ultra V Tech 91 Manual - app. Consult AHRI directory for the latest performance ratings. Jan 8, 2013 · Hot surface ignition using steel shrouded, high density<br />. Multi-Stage Performance and Variable-Speed Dec 28, 2017 · So my furnace is an Armstrong Air Ultra V Tech 80. 81W45 Armstrong induced draft blower; replaces 81W4501 and LB-94724AC. I am pretty sure that the motor is going out on this. Then try it again, leaving the jumper wire in place for about ten to fifteen minutes at a time to see if the unit stays lit. Item model number ‏ : ‎ CECOMINOD034593. Customer Reviews: Armstrong Air Ultra V Advantage 93 Gas 92. If your Armstrong furnace is unregistered, the parts warranty expires after five years, and the lifetime heat exchanger warranty drops to 20 years. old and has an Armstrong Air Ultra V Tech 91 furnace Model # XXXXX We are experiencing a humidity problem that shows itself in a fair bit of con read more Douglas Nov 19, 2011 · 5885 posts · Joined 2011. cleaner, humidifier, furnace twinning, and continuous low<br />. 69W43 Flame Sensor Furnace: 1 PCS OEM Upgraded Qualified Flame Sensor for Furnace Replacement for Compatible with Lennox, Ducane, Armstrong Furnaces - Replace 69W4301 LB-74940B LB74940B. Jul 30, 2012 · I *think* the blower motor on my Armstrong Air Ultra V Tech 91 furnace died after a long, hot summer of nearly constantly using the air conditioning. Distributors for Fasco, Century, Rotom, US Electric Motors and more. Armstrong R06428D406 hot surface ignitor; replaces 06428D406 2019 - Ultra V Tech 80 Furnace Manual Book Reference Armstrong Air Ultra V Tech 91 Parts Manual Results for armstrong air ultra armstrong world industries Ultra V Tech 80 furnace need manual I have an Armstrong Ultra V Tech . Air Conditioner Capacitors. 23. com. 26 No. 99. Quantity: Select all. Like a variable speed air handlers, constant torque air handlers provide lower operating costs and increase overall system efficiency. Solution: Find out that the filter is dirty and that the burner is inflaming. Compared to an older furnace, this can potentially save you hundreds of dollars per year in energy costs. This means 93% of your fuel is converted into usable heat. A Electric forced hot air furnace heats air more quickly than many alternatives, moving air over a heat exchanger or heating coils. Replaces Armstrong ignitor flame rod assembly P/N R42640-001. A: 4-1/8", Wheels List Price: $415. 0 SEER Up To. Save 8% with coupon. com Commitment Item Typically Ships Within the Same Business Day Brand-New Genuine Parts - EverytimeNo Minimum Order MSRP: $309. The igniter connection wasn’t making good contact so the igniter would not igni Top Features of the A802V. Armstrong Air Ultra V Tech 91 I have an Armstrong Air Ultra 5, tech 80 Furnace. For the 45609-101 and R45609-101 you must also replace the motor with Armstrong 10B67, our item 72-K50. 39 $91. change as often as needed,, look at it once a month and decide,, its pretty important in taking care of your system. Oct 15, 2013 · No Additional Cost: You pay $0 for repairs – parts, labor, and shipping included. Air Conditioning Parts. If you cannot locate your part using the above part finder Call or Text Message 1-914-294-2432 (EST) or 1-281-817-1088 (CST) or 1-509-293-9290 (PST) We carry heat relays, sequencers, controls, fan and limit controls, thermostats, thermal cutouts, heater coils, elements, ignitors, hot surface glow bars,contactors, boards, capacitors, capacitors Oct 15, 2013 · If you need a replacement furnace blower for your Armstrong model, check out this 47465-001 Armstrong OEM Replacement Furnace Blower Motor 1/2 HP 115 Volt. 00. Parts for each of these brands can be listed as Ducane, Lennox or Armstrong. 92. 19. $1399. Was: $366. 5 All models. Was getting 4 flashe read more Dec 27, 2010 · I have an Armstrong ultra V Tech 91 gas forced air furnace and the igniter won't ignite - four green lights flash code telling us to reset the limit or rollouts switch but the manual doesn't tell us w read more Jan 4, 2023 · Armstrong Furnace Hvac Parts And Accessories Air Conditioner Refrigerator Partsaps. SKU: R102613-02 Armstrong Air Armstrong Furnace Parts. The Armstrong ultra sx 80 furnace parts diagram is a simple guide to using and installing this furnace. Attempt a time or two more then finally quit. com Armstrong Air Tech 80 Ultra V; Results 1 to 2 of 2 Thread: Armstrong Air Tech 80 Ultra V. ft. Armstrong Air Efv12bcp 1a Thos Somerville Co. ASIN ‏ : ‎ B00RKGZJLM. 06. Jul 13, 2023 · I have an Armstrong Ultra V Advantage 93 furnace. Armstrong Air offers a range of high efficiency gas furnaces with advanced features & performance. Qty. Armstrong 10Y59 program control motor module. Owner Up to 23 . Armstrong 10Y59 control module SKU 72-L29 $495. Gas furnace. limit switch open w Email artwork to dealerartwork@motorsportsdesigns. Web armstrong circuit board shortys hvac supplies. 0 SEER Efficiency *. PRO Series. I cleaned the flame sensor thoroughly three times. Coverage: Plan starts on the date of purchase. QTY: Enlarge Photo. York Replacement Conversion Kit #473-20937-001. 18 Armstrong Ultra V Tech 91 is dated 2009, so many units are still in operation, and some may be available at certain dealers. Coil cleaning. #10 · Nov 19, 2011. Parts Manual Armstrong Air Ultra V Dec 21, 2023 · repair or replace our 20 year old armstrong air ultra v tech 91 Nov 20 2023 we just had an hvac tech recommend we replace our 20 year old original to the house I own an armstrong ultra sx 80 model GUJ100D12-2B with a sv9500h 2724 honeywell smartvalve. 96. Advantage 80 Oil Furnace Armstrong Air Pdf Pdf4pro. Same problem. 45" WC/1. Based on what is seen in this video, a local HVAC tech came to the conclusion that my h. 4 green light flashes apparently indicating "Limit or Rollout switch open". It is made in the USA and has a high customer rating. Mar 23, 2011 · Hi All! I have a 2,300 sq. 5 SEER2 Efficiency*. Pressure switch open with inducer on. TIME: 13. Contractor's Assistant: Did you double-check the thermostat's settings? And what about the filters? Thermo is set to 71, inside temp is 55, and filter appears to be right. in Colorado's Rocky Mtns. S1-02423238001 York 1 HP Fur Mtr. Nov 4, 2021 · I have an Armstrong gas (LP)furnace Ultra Tech 91 Model No G1D91AU100E16C111291. Replaced thermostat, cleaned flame rod. Efficient aluminized steel tapered S-curve. Clean the air conditioner coils. 03-30-2014, 09:06 PM #2. Armstrong-Air Ease-Magic Chef 90% Furnace Draft Inducer. com Logo File Type Information Logo file types needed: Vecor eps / ai files, layered psd files or a high resolution pdf Please advise if there is a specific Pantone color match needed for your logo If you have any questions about the logo file types needed or need Motorsports Designs to check the files you have to make sure they are usable repair or replace our 20 year old armstrong air ultra v tech 91 Nov 20 2023 jan 23 2022 furnace we just had an hvac tech recommend we replace our 20 year old original Nov 4, 2017 · I have an Armstrong gas (LP)furnace Ultra Tech 91 Model No G1D91AU100E16C111291. 5 All models beginning with G2D95L 10/7/04 Armstrong Air Ultra V Tech 90 Gas 90 All models beginning with G1D90 Armstrong Air Ultra V Tech 91 Gas 91 All models beginning with G1D91 Jun 3, 2013 · I have a armstrong air ultra 5 tech 91. Armstrong Air Ultra V Tech 91 Furnaces Armstrong Air Ultra V Tech 91 Manual - app. mrpatelr. HVAC Replacement Parts. This is a BRAND NEW Honeywell Furnace Control Circuit Board. Drops, spills and cracked screens due to normal use covered for portable products and power surges covered from day one. Dec 11, 2009 · Hope this helps. FREE delivery Thu, Feb 29 on $35 of items shipped by Amazon. 45647-001) furnace heating it. Armstrong R06428D406 hot surface ignitor SKU 72-606 $92. 09 each. Blower is running. This manual must be left with the homeowner for armstrong air ultra v tech 91 manual future armstrong air furnace troubleshooting armstrong air ultra v tech 91 parts refere. The video starts right after the first cycle failed to ignite. Armstrong Blower Motor. Chosen by HVAC professionals across the country. 84 This video is dedicated to the average person like myself that just want to know a little more about their furnace parts & it's functions. 00" WC), R102613-02. They are typically located on an inside wall at the back of the house. Armstrong Air Gas Valves. ENERGY STAR® Most Efficient. air conditioner 220-250 Volt Start Capacitors; Armstrong Ultra V Tech 91. 2012 AUTHOR: sivibogg armstrong ultra v tech 90 board Armstrong Support, Manuals & Customer Service - FixYa Armstrong Air: Ultra V Tech 90: 90: All models beginning with G1D90: Armstrong Air: Ultra V Tech 91: 91: All models beginning with G1D91: Bryant: Bryant: 91-92. So you're watching the remaining 4 failed fire attempts. List: $15. Tried the usu read more Dec 11, 2015 · Lennox Armstrong Ducane Furnace Ignitor 70L54 70L5401 20093901 Pilot Assembly in Home & Garden, Home Improvement, Heating, Cooling. Replace the filter, and reset. Honeywell Control Circuit Board Replaces ST9160B1050 ST9160B1068. No A/C, no he read more I have an Armstrong ultra V Tech 91 gas forced air furnace and the igniter won't ignite - four green lights flash code telling us to reset the limit or rollouts switch but the manual doesn't tell us where or how to reset the switch. 5 All models beginning with G1D93 Armstrong Air Ultra V Advantage 93 II Gas 92. Your small, hometown-attitude company Keith Specialty Store 6791 Rt 119 Hwy N, Marion Center, PA 15759 US callers: 800-705-8838 FAX: 724-397-2228 As part of regular furnace maintenance, removing and cleaning the flame sensor can keep things up and running. 5 All models beginning with G2D95L Air-Ease Ultra V Tech 90 90 All models beginning with G1D90 Air-Ease Ultra V Tech 91 91 All models beginning with G1D91 Dec 29, 2014 · Product Dimensions ‏ : ‎ 6 x 6 x 6 inches; 5 Ounces. How much condensate should be in the clear tube going from the inducer to the black rubber boot in the "trap"? Reply. 821002 10KW HEAT STRIP 208-240V FurnacePartSource. With the Pro Series, you’re in control of every aspect of your home’s climate, as well as your energy costs. AC part works nicely, but there is no heat coming out when on "heat". Dec 21, 2023 · ism code imo 2023-09-29 1/4 ism code imo Free epub Ultra v tech 91 furnace manual (Read Only) step 1 ensure the furnace is firmly connected to a working power supply reset the a Lennox International Inc. The most recent literature for the Armstrong Ultra V Tech 91 is dated 2009, Jan 6, 2019 · I have an Armstrong Ultra V Tech 91 that is married to a Bosch heat pump. Armstrong Air affordable heating & cooling products keep you comfortable HVAC Replacement Parts. $189. Locate your circuit breaker box (or electrical panel). Also check that the disconnect switch (located near the air conditioner or heat pump) is ON. It consists of an exploded view of the burner, the igniter, and all the other components in the firebox. Is there anything I can do besides call a c read more Armstrong Furnace 1. ca. FURNACE Diagram and Parts List for GOODMAN Furnace-Parts Armstrong air tech furnace parts armstrong air ultra v tech 80 flame sensor Yesterday we had the gas line added to the existing water heater gas line. TStat still calling for heat and no operation. 5 All models beginning with G2D95L Air-Ease Ultra V Tech 90 90 All models beginning with G1D90 Air-Ease Ultra V Tech 91 91 All models beginning with G1D91 May 3, 2010 · It is about 4 yrs. Also DIY replacement can save a couple hundred Mar 30, 2014 · I have an armstrong air ultra v tech 91 gas furnace that was installed when our home was built in 2004. 5 All models beginning with G2D93L Armstrong Air Ultra V Enhanced 95 Gas 94. First, it would just not get to the temp set on thermostat. P. Best Sellers Rank: #508,665 in Tools & Home Improvement ( See Top 100 in Tools & Home Improvement) #546 in Furnace Replacement Ignitors. OEM HVAC Parts Canada is the OEM online supplier of quality brand new replacements parts for your furnaces, air A circuit breaker may have been tripped in your home. 7 HVAC Replacement Parts. Air-Ease Ultra V Advantage 93 92. yes most Home Depot and Lowe's sells them. Help, it's cold at 9000 ft. How Do I Tell The Age Of An Armstrong Air Furnace Or Conditioner From Serial Number. Choose Options. Blower cleanout. These are the same parts for Allied Air, AirEase, Concord, Ducane, Lennox and others. S1-02425900000 York 15 MFD x 370 Volt Oval Run Capacitor. * Due to Allied Air's ongoing commitment to quality, all specifications, ratings and dimensions are subject to change without notice. Armstrong # 58W01 replaces old numbers 45037-1P, and 45037-001. 22. S1-02423211003 York 3/4 HP Furnace Blower Motor. $99. I have a couple of problems. comArmstrong Air Tech 80 Ultra V; Results 1 to 2 of 2 Thread: Armstrong Air Ultra V 80 Furnace: Hot Surface Ignitor Replacement. 50+ bought in past month. ADD TO CART. I believe it was the air handler blower motor / cage making the noise. Armstrong ultra 80 furnace manual stevenmaples2 s blog. RED LED light is flashing 3 times - System Diagnostic codes on the back of the panel says this means - Pressure switch, rollout switch, or aux. 1) The heat either doe Armstrong 80W97 draft inducer SKU 72-74L $148. Top Features of the A931E. My furnace (Armstrong Air Ultra V Tech 91 Model G1D91BU100D16C) was flashing red three Nov 29, 2020 · I have an Armstrong Air (C2E36C-1A and SA7414 are on the inside unit) with an Ultra V Tech 91 furnace attached. 10. Jan 14, 2024 · Download free Armstrong air ultra v tech 91 manual (PDF) we just had an hvac tech recommend we replace our 20 year old original to the house armstrong ultra v tech 91 model g1d91au100d20c 1a it has been running a lot to keep up with our cold winters and my nest thermostats are notifying me daily that it s running Clever design and durable construction make Armstrong Air package units an excellent all-in-one solution, and a marvel of technology. Date First Available ‏ : ‎ December 29, 2014. Pro Series™ Systems. Armstrong Furnace Parts. Manufacturer ‏ : ‎ Armstrong. Igniter Lennox Armstrong Ducane Furnace Igniter 41K56 41K5601 OEM. Instead of using a paper clip to clear it, I use a 2mm altra armstrong tech advantage 80% field repair kit,kit includes:(1)flame-sensor 44745-001,(1)blower control 45692-001,(1)smart gas valve Armstrong Ultra 77,000 Btu Furnace Wont Ignite DIY Forums, 54% OFF dealers. Error code 3 flashes. I have done some searching on the web regarding this Jan 20, 2012 · Furnace seems to be working, but the fan simply blows out cold air. 5 All models beginning with G2D93L Air-Ease Ultra V Enhanced 95 Gas 94. Show Printable Version; Subscribe to this Thread December 27th, 2007, 03:40 PM #1. Fan motor cleaning & inspection. Compare. I am concerned that it is not draining condensate properly. 91. Dec 29, 2014 · Product Dimensions ‏ : ‎ 6 x 6 x 6 inches; 4 ounces. $159. Jump the R to the W and see if the unit heats up and stays running until you remove the wire. Comfort Sync® A3 Compatible. Welcome to Armstrong Furnace Parts Canada - OEMHvacPartsCanada. Mfg # 66404, Volts 120, RPM 3200. Genuine Lennox, Ducane, Armstrong Two Stage Ignition Control Board, R47583-001. Armstrong Air Switches. Ultra Low NOx model available. FB-RFB203 | Armstrong, Magic Chef, Johnson Air Ease, Olsen Roof top Exhaust blower 230 Volts. Buy your HVAC Parts and Air Filters, with confidence, from professional HVAC technicians with years of experience, who enjoy helping you find the parts that you need. Lennox 19M54 Ignition Control Module Kit. Purchase Armstrong Furnace Blower Motors, Furnace Draft Inducers, Venter Motors on line at discount prices. Refrigerant charge. There's no heat coming out whatsoever. I have an Armstrong Air gas furnace. Armstrong 81W45 draft inducer SKU 72-74R $449. 80% AFUE. And to help you understand why Armstrong Air is The Professional s Choice. The tech checked for obstruction in chimney - none- checked the heat exchan read more Armstrong air ultra v tech 91 manual manuals, be alert to the potential for personal injury or death. Each of these brands share common part numbers. Armstrong 10Y54 programmed control module SKU 72-L24 $590. This is a very helpful tool for anyone that has bought or is about to buy this appliance. company. Dec 27, 2012 · Armstrong Air, Ultra V 80 45647-001. TStat calling for heat furnace comes on and heats the house up too 62F and then cut out. Your dealer will be able to provide: Find the Armstrong Dealer closest to you. Furnaces Qualified Product List; Manual For Armstrong Ultra V compiled pdf, doc, ppt. Now: $338. For clarification, by "blower motor", I'm refering to the electric motor that turns the squirrel cage fan that blows air to the entire house, as shown in the photo below: S1-02420046700 York 10 MFD x 370 Volt Oval Run Capacitor. Everything ran fine no issues. Armstrong Air dealers are trained and have all the necessary qualifications in place to find the ideal fit for your needs and budget. Feb 21, 2024 · Armstrong furnaces all come with a 10-year parts warranty, as well as a lifetime warranty for the heat exchanger, as long as you register the furnace within 60 days of installation. Two days ago it smelled like burnt rubber coming out of the registers. True Variable-Capacity Cooling. The fan is blowing but the burners are not even attempting to ignite. Can't even turn off heat using the thermostat. Up to 21. two story home with an Armstrong Air ULTRA 5 TECH 80, (Model No. Pair this model with a Pro Series™ variable-capacity or two-stage air conditioner or heat pump and a Comfort Sync thermostat, for optimum performance. We woke this morning to 42F in the house and the thermostat was Armstrong Air Ultra V Advantage 93 II Gas 92. There should be a wiring diagram of the unit on the inside of one of the furnace doors. How Do I Troubleshoot A Armstrong Air Ultra V Tech 91 Furnace Ehow. wordtail. 95. Add to List a Armstrong Air Ultra V Tech 91 I have an Armstrong Air Ultra 5, tech 80 Furnace. Armstrong Air Conversion Kits. ASIN ‏ : ‎ B00RKGYSPA. Multi-Stage Performance and Variable-Speed Blowers. SKU: R47583-001 Armstrong Air Sep 12, 2014 · sensor rod is clean, sensor is clean, flames hit the sensor, pilot light coming back on, won't stay lit, stays on for about a count of 5, now flashing 7 again, smelling gas, only temporary. Description. Looking at a Calculated at Checkout. Armstrong Furnace is a division of Lennox Corporation and shares the same model number with units that are branded as Ducane. $ 128. Air Handler Blower Motor S89-682. Nov 29, 2008 · If the terminal board on the furnace has wires hooked up to R, W, Y, G then buy a single stage type of tstat. Permanently lubricated draft motor with stainless steel<br />. Thread Tools. Model is G1D91BU100D16C-1A if this helps any. 90. Armstrong Air Ultra V Advantage 93 II Gas 92. As with any mechanical. Add To Cart. Burner will ignite temporarily and go out. Check all major components and safety devices for heating and Fasco D1127 3. Built with durable materials and incorporating brilliant technology throughout, Armstrong Air is not only the brand to trust with your home comfort, it’s also the brand more It takes smart planning by a skilled expert to get you the right heating, cooling, humidity control and energy efficiency for your home. Ships: Immediately. 5 All models beginning with G2D95L Armstrong Air Ultra V Tech 90 Gas 90 All models beginning with G1D90 2 Armstrong Air Ultra V Tech 80 Manual 2022-11-06 HVACArmstrong Air Ultra V Tech Armstrong Air Ultra V Tech 91 Furnace Overview The Armstrong Ultra V Tech 91 furnace is a discontinued gas furnace that can achieve an AFUE rating of up to 91 percent. Schematic Representation Of The Experimental Setup A Cooling Plant Scientific Diagram. I cleaned the flame s Ultra Member. Then last night it they was a rumbling noise coming from the furnace closet. Check the circuit breaker box and make sure breakers are in the ON position. Armstrong Furnace Parts Catalog Replacement for Armstrong/Ducane/Goodman and Lennox Replacement Condenser Fan Motor. Fan control board features adjustable fan off time in the<br />. Since 1928, Armstrong Air has been the smart choice for homeowners who expect more from their heating and cooling system. Best Sellers Rank: #1,005,888 in Tools & Home Improvement ( See Top 100 in Tools & Home Improvement) #1,178 in Furnace Replacement Jan 2, 2023 · Overview of how to replace the gas valve on an Armstrong Ultra SX 80 furnace. The enormous available bandwidth, the wide scope of the data rate / rangetrade-off, as well as the potential for very low-cost operation leading Oct 16, 2018 · Hi,We have an Armstrong Air, Ultra V Tech 90 furnace, and are having difficulties with it coming on when the thermostat calls for heat. 5 All models beginning with G2D93L 10/7/04 Armstrong Air Ultra V Enhanced 95 Gas 94. Armstrong Air Parts. Fan control board provides terminals for electronic air<br />. Mar 6, 2009, 09:31 PM. No ignition. Blower fan running constantly. filter location=somewhere in the return air part of the system,, probably around the blower motor section or possibly behind return air grill. HVAC Technician: BillyHvac. 45. sku: Armstrong Furnace Parts. It is not doing anything now--put thermostat fan on "On", nothing happens. 601XBM 41-605 Mini Furnace Igniter (plus Harness and Bracket) Part #: 41-605. Armstrong 80W97 induced draft blower; replaces 101431-01, 101514-01, 80W9701, R101431-01 and R101514-01. Trane AC and Heat Pump Condenser Fan Motors. It's designed to replace all the Honeywell part #s listed below. Duralight Furnace Hot Surface Ignitor Direct Replacement For Lennox Armstrong Ducane OEM How do i troubleshoot a armstrong air ultra v tech 91 furnace ehow. jx jv cc zb al yr ua rx el ci